Skip to main content

OneBio Research

Independent third-party lab reports for OneBio Research lots. Each report is matched to the lot number printed on the vial and covers only the lot that was tested.

What the numbers mean

  • Purity (HPLC): the share of the sample that is the target peptide.
  • Potency / content: how much peptide is in the vial compared with the label.
  • Identity (FTIR or LC-MS): confirms the vial holds the right compound.
  • Lot number: match it to the lot printed on your vial.

Published reports

GLP-3 RT (retatrutide) 60 mg — lot OBR-260607-GLP05

Freedom Diagnostics · received August 13, 2026 · reported August 19, 2026 · accession 2608131016

  • HPLC purity: 99.89%
  • Net content: 57.71 mg (96.2% of the 60 mg label)
  • Identity: retatrutide confirmed by LC-MS

View the full lab report (PDF)

This report does not include endotoxin, sterility or microbial testing.

GLP-3 RT (retatrutide) 60 mg — lot RT001

BT Labs, West Palm Beach, FL · tested June 1, 2026 · report IF-824-QSA-TR006-BTL26607-01

  • HPLC purity: 99.8% (specification ≥ 98%)
  • Measured content: 62.7 mg (104.5% of the 60 mg label)
  • Identity: retatrutide confirmed by FTIR

View the full lab report (PDF)

This report does not include endotoxin, sterility or microbial testing.

BPC-157 10 mg — lot BC001

BT Labs, West Palm Beach, FL · tested June 1, 2026 · report IF-824-QSA-TR006-BTL26607-02

  • HPLC purity: 99.7% (specification ≥ 98%)
  • Measured content: 10.0 mg (99.6% of the 10 mg label)
  • Identity: BPC-157 confirmed by FTIR

View the full lab report (PDF)

This report does not include endotoxin, sterility or microbial testing.

TB-500 10 mg — lot TB001

BT Labs, West Palm Beach, FL · tested June 1, 2026 · report IF-824-QSA-TR006-BTL26607-03

  • HPLC purity: 99.7% (specification ≥ 98%)
  • Measured content: 9.7 mg (96.9% of the 10 mg label)
  • Identity: TB-500 confirmed by FTIR

View the full lab report (PDF)

This report does not include endotoxin, sterility or microbial testing.

MOTS-c 40 mg — lot MS001

BT Labs, West Palm Beach, FL · tested June 1, 2026 · report IF-824-QSA-TR006-BTL26607-04

  • HPLC purity: 99.8% (specification ≥ 98%)
  • Measured content: 47.8 mg (119.4% of the 40 mg label)
  • Identity: MOTS-c confirmed by FTIR

The measured content is above the lab’s 90–110% potency range: this vial held more peptide than its label states.

View the full lab report (PDF)

This report does not include endotoxin, sterility or microbial testing.

More reports are added as lots come back from the lab. To ask about documentation for your lot, contact us with the lot number on your vial.

Research Use Only: All OneBio Research products are for laboratory research only. Not for human or animal consumption.